FitsMyPool

Does a filter system from Steinbach fit a pool from Intex?

Partly documented. For some Steinbach devices there is a documented route to Intex pools — through the connection parts shown in green under the connections below. What exactly is needed is on the page of each device and each pool. For all other connections it remains: not documented.

What this is about

This concerns 65 recorded Intex pools and 34 Steinbach devices: 30 Sand filter systems, 3 Filter ball pumps, 1 Cartridge filter pumps.

The connections

Every manufacturer has its own connection types. The same nominal size does not mean the same connection — the number describes the width, not the coupling.

  • Intex 32 mm (1.25 in) → Steinbach Ø 32 mm no part documented
  • Intex 32 mm (1.25 in) → Steinbach Ø 38 mm no part documented
  • Intex 32 mm (1.25 in) → Steinbach Ø 50 mm no part documented
  • Intex 38 mm (1.5 in) → Steinbach Ø 32 mm no part documented
  • Intex 38 mm (1.5 in) → Steinbach Ø 38 mm no part documented
  • Intex 38 mm (1.5 in) → Steinbach Ø 50 mm no part documented
  • Intex 32 mm (1.25 in) → Steinbach pre-filter lid, 1 ½" female thread documented paths: 1
  • Intex 32 mm (1.25 in) → Steinbach 7-way valve, 1" male thread documented paths: 1
  • Intex 38 mm (1.5 in) → Steinbach pre-filter lid, 1 ½" female thread documented paths: 1
  • Intex 38 mm (1.5 in) → Steinbach 7-way valve, 1" male thread documented paths: 1

Threads, where recorded

  • Intex 38 mm (1.5 in): 2 in Derived from manufacturer data
  • Steinbach pre-filter lid, 1 ½" female thread: 1.5 in Derived from manufacturer data
  • Steinbach 7-way valve, 1" male thread: 1 in Derived from manufacturer data

Where the figure is missing, that is not a statement about fit but a gap in the source.

What would settle the question

  • An adapter whose manufacturer names both connections — then the path would be documented and would appear in the results of every pool concerned.
  • A manufacturer statement that two connection types are interchangeable. Our register currently holds not a single one.
  • Thread and diameter measurements of both sides from a primary source. Then the question could be calculated rather than looked up — and the result would probably be a documented exclusion, not a free pass: where two threads are recorded today, they differ at the same nominal size. The check does not yet know the thread and therefore stays at “unknown”; with two derived values that restraint is appropriate.

What is documented

Within one manufacturer things look different. Which devices fit a particular pool is stated on the page of that pool: all recorded Intex pools .